  specification mdr-100-12 mdr-100-24 mdr-100-48 model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time note.5 hold up time (typ.) voltage range note.6 frequency range efficiency (typ.) ac current (typ.) input inrush current (typ.) safety standards harmonic current ems immunity working humidity working temp. storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage 12v 24v 48v 7.5a 4a 2a 0 ~ 7.5a 0 ~ 4a 0 ~ 2a 90w 96w 96w 120mvp-p 150mvp-p 24 ~ 30v 200mvp-p 48 ~ 56v 1.0% 1.0% 1.0% 12 ~ 15v 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 3000ms, 50ms/230vac 3000ms, 50ms/115vac at full load 50ms/230vac 20ms/115vac at full load 85 ~ 264vac 120 ~ 370vdc 47 ~ 63hz 85% 86% 88% 1.3a/115vac 0.8a/230vac cold start 30a/115vac 60a/230vac 105 ~ 150% rated output power protection type : constant current limiting, recovers automatica lly after fault condition is removed protection type : shut down o/p voltage, re-power on to recover 15.6 ~ 18v 31.2 ~ 36v 57.6 ~ 64.8v -10 ~ +60 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 component : each along x, y, z axes ; mounting : compliance to iec60068-2-6 10 ~ 500hz, 2g 10min./1cycle, period for 60min. 346k hrs min. mil-hdbk-217f (25 ) 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. length of set up time is measured at first cold start. turning on/off the powe r supply may lead to increase of the set up time. 6. deating maybe needed under low input voltages, please check the derati ng curve for more detail. file name:mdr-100-spec 2011-03-22 ul508, tuv en60950-1 approved compliance to en61000-3-2,-3 96w single output industrial din rail power supply m d r - 1 0 0 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 environment protection safety & emc (note 4) withstand voltage isolation resistance emi conduction & radiation universal ac input / full range protections: short circuit / overload / over voltage / over temperature zcs/zvs technology to reduce power dissipation cooling by free air convection can be installed on din rail ts-35/7.5 or 15 dc ok relay contact no load power consumption<1w led indicator for power on 100% full load burn-in test 3 years warranty features : 55*90*100mm (w*h*d) 0.42kg; 30pcs/13.6kg/0.82cuft leakage current <1ma / 240vac i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:>100m ohms / 500vdc / 25 / 70% rh function dc ok signal relay contact rating(max.): 30v/1a resistive compliance to en55011, en55022 (cispr22), en61204-3 class b compliance to en61000-4-2, 3, 4, 5, 6, 8, 11, env50204, en55024, en61000-6-2, en61204-3, heavy industry level, criteria a over temperature 90 10 (rth2) detect on heatsink of power transistor protection type : shut down o/p voltage, re-power on to recover power factor (typ.) pf 0.95/230vac pf 0.98/115vac at full load
mechanical specification file name:mdr-100-spec 2011-03-22 block diagram dc ok relay contact -10 0 10 20 30 40 50 60 70 (vertical) 20 40 60 80 100 ambient temperature ( ) load (%) circuit detection o.l.p. o.t.p. emi filter & rectifiers pfc circuit power switching filter & rectifiers +v dc ok -v i/p pwm pfc control control o.v.p. o.c.p. output derating vs input voltage input voltage (vac) 60hz 85 100 95 120 115 160 140 200 180 240 220 264 load (%) ta=25 90 100 80 70 60 50 40 derating curve + install din rail ts35/7.5 or ts35/15 35 +v +v 90 55 -v -v n l dc ok dc ok +v adj 5 5 5 5 5 7.5 7.5 100 case no.973a unit:mm fg contact close psu turns on / dc ok. psu turns off / dc fail. 30v/1a resistive load. contact open contact ratings (max.) 96w single output industrial din rail power supply m d r - 1 0 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of MDR-10011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X